Yes, it is.
Read the whole answerVacuum contactors use encapsulated contacts with vacuum instead of air as the medium to eliminate arcing. Vacuum contactors are only...
Read the whole answerYes, we at INKOM have our own assembly department that does customized final assembly, etc.
Read the whole answerYes, all system solutions are in accordance with TSFS 2020:88.
Read the whole answerAll side channel fans with 3-phase motors can be speed controlled with frequency converters.
Read the whole answerElectric side channel fans are standard equipped with IE2 motors in accordance with IEC 60034-30.
Read the whole answerWatch this video explaining it
Read the whole answerThis question must be broken down into several parameters. The amount of current that can flow through the contactor continuously...
Read the whole answerIn each contactor there is a coil that operates switching and breaking, the voltage to control the coil can vary...
Read the whole answerThe contactor can either be controlled to one mode or both modes, for switching on or off. For example, a...
Read the whole answerHigh short-circuit currents and an unregulated closing with load is the most common reason for the contactor to weld. This...
Read the whole answerNO = Normally Open, NC = Normally Closed. This describes the state of a contactor when the voltage in the...
Read the whole answerWhen an electromechanical component such as a contactor is exposed to a situation that causes it to fail, it does...
Read the whole answerIt will form an arc with a lot of energy. The best way to extinguish it is with permanent magnets...
Read the whole answerFor each contactor, there is a short-circuit current and a time that it must withstand. If this is higher and...
Read the whole answerA contactor is defined according to IEV ref 441-14-33 as a mechanical switching device with only one rest position, operated...
Read the whole answerAn economizer is an electronic circuit that regulates (PWM) the turn-on power and hold power of the coil. An economizer...
Read the whole answerTraditionally, contactors have worked with coils to force the arc to the arc chamber for extinguishing. During arc formation, the...
Read the whole answerWhen breaking both + & and – in case of anomalies in the system.
Read the whole answerPre-charge, in the context of a DC (direct current) system, refers to a process of gradually charging the capacitance or...
Read the whole answerSR and SRM linen stoppers are approved according to IEC 947-5-5, DIN EN 60947-5-5 and ISO 13850.
Read the whole answerHistorically, contactors have been used to directly switch on and off electrical loads, such as electric motors, and even today...
Read the whole answerA contactor is a vital safety component in any electrical system, Schaltbau stands for new patented technology. By far the...